Fire risk assessment for a block of flats

Mansion blocks, converted houses, estates and new towers. Common parts, flat entrance doors and the duties to residents.

  • Written report to keep on file
  • Clear action plan, highest risk first
  • Price agreed before booking
Get a price

We reply with a written price.

We use these details to reply to you. See our privacy notice.

Mansion blocks

Battersea, Balham and Putney have plenty of red-brick mansion blocks from around 1900. Wide stone or timber stairs, a lift added later, servants' stairs at the back that may now be locked or blocked with bikes, coal cellars turned into storage, panelled flat doors, a roof full of water tanks. The assessment asks whether the main stair is still a protected route, whether the back stairs still work as a second way out, and whether the old doors hold back smoke.

A communal corridor with blue walls and a flat entrance door with a brass knocker
A communal corridor with blue walls and a flat entrance door with a brass knocker

Converted houses

Three to six flats in a big Victorian house. One stair, meters in the hall, a basement flat with its own door, roof flats at the top. Often no alarm in the common parts, only smoke alarms inside each flat. The question is whether that is enough for this building, and the answer depends on the layout, the doors and who lives there.

Estates and towers

Post-war blocks at Roehampton and across the borough, and new towers at Nine Elms and Battersea. Smoke vents, dry risers, firefighting lifts, refuse chutes, bin rooms, plant rooms. For 18 metres or seven storeys and up, the high-rise duties: floor plans and a building plan for the London Fire Brigade, a secure information box, wayfinding signs, monthly checks of lifts and firefighting equipment.

Every block with two or more flats

Fire safety instructions to residents, and information about fire doors. Since the Fire Safety Act 2021, the flat entrance doors, structure and external walls fall within the Fire Safety Order. Over 11 metres: communal fire doors checked every three months, flat entrance doors every 12 months as far as possible.

Type 1 to 4

From the LGA guide on purpose-built flats. Type 1, common parts, nothing opened up, is normally enough for most purpose-built blocks. Types 2 to 4 add destructive inspection, flats, or both.

Got a building that needs assessing?

Give us the postcode and the use of the building and we will send a written price.

Call 020 4572 9222Get a quote